Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38727787

RESUMO

A 73-year-old male was admitted because of recurrent syncope. He was diagnosed with transient bradycardia caused by a 2:1 atrioventricular block, and he underwent cardiac computed tomography (CT) using 320 detector-row CT to screen for coronary artery disease. Significant coronary artery stenosis was not detected, but diffuse late iodinate enhancement was found on the epi-myocardium and endo-myocardium of the interventricular septum, and endo-myocardium of the anterior and lateral left ventricular (LV) myocardium (LVM) on CT. The ejection fraction and global longitudinal strain (LS) of LVM were 53.97% and - 9.87% on CT. Apical sparing was present, meaning the LS of LV apical segments were preserved compared with basal segments on CT. Pathological findings of LVM demonstrated loss of myocardial cells and extra-cellular amyloid deposition on the direct fast scarlet staining. He was finally diagnosed with transthyretin amyloidosis.

5.
Intern Med ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38346744

RESUMO

Objective Although magnetic resonance imaging (MRI) is the gold standard for evaluating abnormal myocardial fibrosis and extracellular volume (ECV) of the left ventricular myocardium (LVM), a similar evaluation has recently become possible using computed tomography (CT). In this study, we investigated the diagnostic accuracy of a new 256-row multidetector CT with a low tube-voltage single energy scan and deep-learning-image reconstruction (DLIR) in detecting abnormal late enhancement (LE) in LVM. Methods We evaluated the diagnostic performance of CT for detecting LE in LVM and compared the results with those of MRI as a reference. We also measured the ECV of the LVM on CT and compared the results with those on MRI. Patients or Materials We analyzed 50 consecutive patients who underwent cardiac CT, including a late-phase scan and MRI, within three months of suspected cardiomyopathy. All patients underwent 256-slice CT (Revolution CT Apex; GE Healthcare) with a low tube-voltage (70 kV) single energy scan and DLIR for a late-phase scan. Results In patient- and segment-based analyses, the sensitivity, specificity, and accuracy of detection of LE on CT were 94% and 85%, 100% and 95%, and 96% and 93%, respectively. The ECV of LVM per patient on CT and MRI was 33.0% ±6.2% and 35.9% ±6.1%, respectively. These findings were extremely strongly correlated, with a correlation coefficient of 0.87 (p <0.0001). The effective radiation dose on late-phase scanning was 2.4±0.9 mSv. Conclusion The diagnostic performance of 256-row multislice CT with a low tube voltage and DLIR for detecting LE and measuring ECV in LVM is credible.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...